Search results
- ${ip_host}^10\.0\.=-;error=forbidden;reason=Your IP range is blacklisted ; Using $name=value will instead change the global variable with that name.20 KB (3,110 words) - 10:27, 4 November 2013
- Show or change [[Debug_Output|debugging level]] globally or per module * '''drop''' {chan|*|all} [reason]2 KB (335 words) - 13:12, 13 May 2013
- * control which Caller ID uses SIP client and change it to allowed from predefined range; ...tion} s' ,INTERVAL '${billtime} s',INTERVAL '${ringtime} s','${status}','${reason}',false)14 KB (2,155 words) - 10:47, 11 January 2014
- After the INVITE completes successfully the codes are sent in the Reason: header of the BYE transaction. [[Category:SIP]] [[Category:H323]] [[Category:IAX]] [[Category:Change reason]]3 KB (380 words) - 09:25, 4 November 2013
- ...p settings, if one span fails to be created the whole group will fail. The reason is the fact that there is no way to find out how many circuits the span wou Incoming calls must be pre-routed. The reason is the absence of the called party number (and, possible, the caller party17 KB (2,660 words) - 08:04, 21 June 2018
- * '''autoaddr''': bool: Auto change outgoing RTP address:port to match incoming. This will drop the call with reason ''nomedia'' 6.5 seconds after no RTP or RTCP packets were received. The 6.56 KB (870 words) - 14:12, 10 January 2014
- Yate will use the default port, so will change the port for YateClient. The reason for which it isn't needed to install YateClient separately: running YateCli12 KB (1,986 words) - 15:13, 31 October 2013
- ...e.notify''' is a message sent by a module to notify a resource event state change or a subscription termination :Optional subscription termination reason if subscriptionstate is terminated2 KB (219 words) - 15:22, 21 January 2013
- ... only if they are installed in the distribution's default location. If you change the location then you have to specify the path like this: * A reason that the module is not loaded may be that you don't have the devel packages5 KB (810 words) - 11:18, 4 November 2013
- :*'''reason'''=true ( a (mostly) human readable reason for this CDR ) The "operation" parameter indicates the state of the call and the reason why the message was sent.10 KB (1,558 words) - 13:22, 13 January 2014
- ...ions. We do this mainly because if one module is changing we don't have to change all the other modules that are dependent, and also because we can debug wha * The order this does not change between messages.8 KB (1,217 words) - 20:38, 10 March 2014
- This script is given as an example, don't forget to change some information such as yate's extmodule binding ip address and port. if notify['reason'] == 'eof':9 KB (821 words) - 12:17, 4 November 2013
- When starting Yate with logging, [[rmanager]] module can be used to change the levels for debugging. By doing this the debugging messages will be seen Show or change debugging level globally or per module:7 KB (905 words) - 15:03, 14 October 2016
- Always from the application to the engine, requests the change of a local parameter<br/> The answer to the change request is delivered asynchronously (see below).<br/>15 KB (2,320 words) - 15:19, 24 March 2016
- if (msg.reason == "congestion") msg.reason = "busy";2 KB (242 words) - 16:09, 31 October 2013
- ...ted_messages''': Number of requests rejected at connection layer. Possible reason: unsupported command, application, unsupported protocol version Request send may fail (due to remote application support change, connection failure ...) or the request may time out.<br>43 KB (6,355 words) - 13:27, 1 October 2019
- ...the gateway has a list of SS7 layers 2 under his supervision; and it will change their state only if the active clients requested so. This behavior will let ...ed with Node 1 and Node 2, each of them with it's own Point Code. For some reasons, let's say security issues or network design, we do not want to process th13 KB (2,284 words) - 11:12, 13 December 2017
- ...an lock its local end of a circuit for maintenance and/or hardware failure reasons. * remotehw: Remote end of the circuit is locked for hardware failure reason36 KB (5,180 words) - 12:18, 26 October 2017